x
I n k a r p

BWB SUGAR Flame Photometer

BWB SUGAR Flame Photometer
Distributor & Service Provider In India

Inkarp Instruments, a trusted BWB Technologies partner, introduces the BWB SUGAR Flame Photometer in India, a specialized instrument for sugar and beverage analysis.

Redefining Sugar refining from beet or cane

  • Uniquely hybridized bwb dual channel, focused for high accuracy potassium And sodium measurements
  • “IRS” (internal reference standard) available
  • 4-20ma 2 wire output compatible with scada software
  • Live online monitoring
  • Constant condensation stream feeds with use of the proprietary bwb collection cup
  • Built-in air compressor; pioneered by bwb technologies in 2007 and proven now with over 1000 units in global field use
  • Solutions and labware included; “just add gas”, the hallmark of the user friendly bwb flame photometer (fes) program
  • User selectable decimal places
  • Intuitive user interface for true ease of use
  • Display prompts step by step operation
  • Data sharing via pc link with bwb’s FP/PC app

    Technical Data

Sample rate 2 – 3.5ml/min
Tubing materials Silicone and Tygon®
Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D)*
For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney.
Instrument size Li Flame Photometer
51cm (H) x 39cm (W) x 35cm (D)
(20in x 15in x 14in)
Shipping 65cm (H) x 49cm (W) x 43cm (D)
(25in x 19in x 17in)
Weight Soil Flame Photometer – 14kg (30.8lbs)
Shipping – 25kg (55.1lbs) ​
Optimal range Single point calibration
Na 0.1 – 60ppm
K 0.05 – 100ppm

Multi Point Calibration
Na 0.1 – 1000ppm
K 0.05 – 1000ppm
Reproducibility < 1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm equivalent or less. (After instrument stabilisation).
Specificity Na/K/Li = < 1% to each other when
equal in concentration at <100ppm
Limit of detection (LOD) and
limit of quantification (LOQ)
LOD
Na – 0.03ppm
K – 0.02ppm
LOQ
Na – 0.1ppm
K – 0.05ppm
Time to stability Less than 15 seconds after sample
is introduced into the flame
Ions measured   Potassium
Sodium
Interfaces USB
4-20mA output capable of direct link to SCADA systems
Optional integrated printer
.CSV and .PDF generated reports and files via FP-PC software
Collection Cup providing 24/7 live automated sampling*
Recommended minimum warm up
time based on ambient temperature
21°C – 25 minutes
Power requirements 100V – 250V AC at 50 or 60Hz
automatically selecting
Fuel requirement Propane, Butane or Natural Gas* regulated to 19Bar. Flow rate of 0.4l/min
*with modifications. BWB Technologies recommends either Propane or Butane for optimum results.
Readout LCD, four line, alpha numeric, back lit.