x
I n k a r p

The BWB BIO Flame Photometer

The BWB BIO Flame Photometer

Purpose Built Flame Photometer with specialised software,
firmware and hardware

  • Specially configured for a range of user interests
  • “IRS” (internal reference standard) caesium or lithium option
  • single point calibration correction
  • internal reference standards
  • 5 and 6 point multi-ion calibration standards for urine and serum included
  • analysing li and ca along with na and k
  • operator independent determination of results
  • advanced automated determination of results
  • integrated printer with environmentally friendly ink
  • IQ, OQ, PQ web-based certification standard on bio and available on all bwb fes units
  • Correction of ca for the interference from high levels of NA
  • Technical Data
Sample rate 2 – 3.5ml/min
Tubing materials Silicone and Tygon®
Specificity Na/K/Li = <1% to each other when
equal in concentration at <100ppm
Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D)*
For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney.
Instrument size XP Flame Photometer
51cm (H) x 39cm (W) x 35cm (D)
(20in x 15in x 14in)
Shipping 65cm (H) x 49cm (W) x 43cm (D)
(25in x 19in x 17in)
Weight BIO Flame Photometer 14kg (30.8lbs)
Shipping 25kg (55.1lbs)
Optimal range Multi-point calibration
Na – 0.0043 – 300mmol/l*
K – 0.0013 – 200mmol/* 
Li – 0.0072 – 20mmol/l*
Ca – 0.025 – 20mmol/l*
*With required Dilution Ratios
Reproducibility < 1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm equivalent or less. (After instrument stabilisation).
Limit of detection (LOD) and
limit of quantification (LOQ)
LOD
Na – 0.0013mmol/l
K – 0.0005mmol/l
Li – 0.003mmol/l
Ca – 0.0075mmol/l
LOQ
Na – 0.0043mmol/l
K – 0.0013mmol/l
Li – 0.0072mmol/l
Ca – 0.025mmol/l
Time to stability Less than 15 seconds after sample
is introduced into the flame
Ions measured   Serum Na and K or Li and Ca
Urine Na and K or Li and Ca


Calibration concentrations
URINE
Point 1
Na 25mmol/l
K   25mmol/l
Li   2.5mmol/l
Ca 2.5mmol/l
Point 2
Na 50mmol/l
K   50mmol/l
Li   5mmol/l
Ca 5mmol/l
Point 3
Na 100mmol/l
K   100mmol/l
Li   10mmol/l
Ca 10mmol/l
Point 4
Na 200mmol/l
K   150mmol/l
Li   15mmol/l
Ca 15mmol/l
Point 5
Na 300mmol/l
K   200mmol/l
Li   20mmol/l
Ca 20mmol/l
SERUM
Point 1
Na 120mmol/l
K   3mmol/l
Li   0.25mmol/l
Ca 1.5mmol/l
Point 2
Na 130mmol/l
K   4mmol/l
Li   0.5mmol/l
Ca 2mmol/l
Point 3
Na 140mmol/l
K   5mmol/l
Li   1mmol/l
Ca 2.5mmol/l
Point 4
Na 150mmol/l
K   6mmol/l
Li   1.5mmol/l
Ca 3mmol/l
Point 5
Na 160mmol/l
K   7mmol/l
Li   2mmol/l
Ca 3.5mmol/l
Recommended minimum warm up
time based on ambient temperature
21°C – 25 minutes
Power requirements 100V – 250V AC at 50 or 60Hz
Fuel requirement Propane, Butane or Natural Gas* regulated to 19Bar. Flow rate of 0.4l/min
*with modifications. BWB Technologies recommends either Propane or Butane for optimum results.
Readout LCD, four line, alpha numeric, back lit.