x
I n k a r p

Reichert® 4SPR

Reichert® 4SPR
Distributor & Service Provider In India

The More Flexible, More Powerful, More Affordable 4-Channel SPR.

With Reichert, you get a four-channel surface plasmon resonance (SPR) system that provides outstanding data, with a 30-70% lower total cost of ownership over five years as compared to equivalent performing systems.

Reichert Gives You:

  • High-quality, publication-ready data
  • More flexibility (analyze crude samples, interface with other equipment)
  • Easy-to-use software with guided workflows
  • The best performance-to-cost ratio for individual labs
  • A proven SPR leader since 1997

To see how Reichert can help advance your research and lead to new breakthroughs, contact us today to schedule a demo in your lab.

    Technical Data

Measurement Channels Four
Sample Loading Autosampler. Up to 768 samples
Injection Volume 1 uL to 4,500 uL (depends on installed loop volume)
Buffer Degasser Built-in
Temperature Range 10°C below ambient to 70°C
Sample Storage 4°C or ambient temperature
21 CFR Part 11 Compliant

  • MEASUREMENT SENSITIVITY
Baseline Noise 0.05 uRIU (RMS)
Baseline Drift < 0.1 uRIU/min
Minimum Molecular Weight Detection No lower limit for organic molecules

  • TYPICAL KINETIC AND EQUILIBRIUM CONSTANT RANGES
Association Rate Constant 103to 108M-1s-1
Dissociation Rate Constant 10-1to 10-6s-1
Equilibrium Dissociation Constant 10-3to 10-12M

  • Compare the Reichert4SPR to Cytiva Biacore™ T200

The Reichert4SPR, is the new standard for Surface Plasmon Resonance (SPR) instrumentation. Our 4-Channel system features high sensitivity with maximum flexibility and uptime to meet even your most demanding applications. The Reichert4SPR provides more value by featuring easy-to-access fluidics, lower operating and maintenance costs, and maximum flexibility with no compromise in performance.

Reichert4SPR Cytiva Biacore T200
Number of Channels 4 4
DIY Fluidics Yes No
Autosampler Capacity Maximum 768 samples Maximum 462 samples
Baseline Drift 0.1 RU/min < 0.3 RU/min
Baseline Noise 0.05 RU(RMS) 0.03 RU(RMS)
Specialized Flow Cells Electrochemistry, Photochemistry,
Fluorescence, Mass Spectrometry
None
Temperature Range 10°C below ambient to 70°C 4 - 45°C
Flow Rate Range 0.1 - 3000 µL/min 1 – 100 µL/min
Minimum Molecular Weight Detection No lower limit for organic molecules No lower limit for organic molecules

Webinars

Upcoming Webinars

Master Polar Analyte Separation: Expert Tips for Chromatographers